Reference shoot guides for the Recycled Sound device register. Pick the section that matches the device shape you're capturing - you only need ONE set per device.
Scanner identify protocol - the 6 rules that make a scan succeed. This is separate from the full reference shoot below (which captures all six faces for the register). To identify a device, the app only needs one good photo of the brand-label face - but it must follow these six rules. Validated 2026-06-18 against real hand-held photos: when all six held, the scanner read the brand ("ReSound"); when the device was held in a fist or shown thin-edge-on, nothing read at all - and no smarter model fixes a label that isn't pointing at the camera.
Show the brand-label face. Brand and model are read by OCR off the printed label. Depending on the make it's on the inner (medial) face or the battery-door end - point that face at the camera. If the label isn't visible, there is nothing to read. (In testing, a device shown battery-door-up read only "CE"; the same device label-up read the brand.)
Hold at the fingertips - never fist it. Fingers wrapping the body hide the device outline, so the scanner sees "an object in a hand" and can't lock on. Pinch one end so the whole body and label are exposed. (Occlusion - not poor light - was the difference between a read and a blank in testing.)
Fill the frame - move in close. The label text is tiny; at arm's length it's only a few dozen pixels wide and OCR grabs fragments ("Rel" instead of "ReSound"). Get the device filling most of the frame. (You can't fix this afterwards - enlarging a far-away photo does NOT recover the detail.)
Get it sharp. Tap to focus or use macro; hold ~10-15 cm away. A soft, blurry label is unreadable no matter how good the lighting.
Plain, contrasting background. A dark device against a dark couch or skin blurs the edge. A plain, light surface gives a clean outline. (Helps the device stand out; brightness alone is not the lever - presentation is.)
Hold still a beat. The app waits for the device to stop moving before it captures - a still frame is sharp by construction. Rest your hand and pause.
What kills a scan (each one cost a failed identify in testing): label face hidden (showing the shell or battery door instead) · fingers wrapping the body · device shown thin-edge-on · device tiny in the frame · motion blur.
One set per shape class. The two BTE protocols below cover the same 6 anatomical orientations - they're not additive. Default to the hand-held naturals flow. The table rig is legacy: kept for reference, but real-world testing showed hand-shots outperformed calibrated rig shots for training data (22/22 naturals worked; ~3 rig attempts failed). Non-BTE shapes and accessories ARE additional - take those when you encounter them.
1. BTE hand-held naturals
Hand-shot photos of BTE aids held naturally between thumb and index finger. This is the recommended protocol for training data: natural hand-shots match the deployment distribution better than calibrated rig shots.
Why this beats the table rig: in real testing, hand-shot naturals outperformed calibrated table-rig capture for training data. The scanner sees devices in volunteers' hands, not on tables - so train it that way. 22/22 naturals worked; ~3 scaled-protocol attempts failed.
Shoot order: L aid first (all 6 orientations, shots 1-6), then R aid (shots 7-12). Shoot a couple of extra angle variants of the medial (label) face if the print is hard to read - natural variation helps the model.
Anatomical naming: medial = inner (touches head, label-side); lateral = outer; anterior = front edge; posterior = back edge; superior = top end (hook); inferior = bottom end (shell base).
Lighting: indoor diffuse light. Avoid harsh shadows from overhead bulbs - face a window or use a soft lamp.
Framing: phone camera at arm's length, device fills roughly 60% of frame.
1. Lateral face up
L: shot 1.R: shot 7
Outer shell faces camera. No label visible.
Hand grip view
Pinch shell at posterior edge; lateral face points up at camera.
2. Medial face up
L: shot 2.R: shot 8
Inner side faces camera. Label visible. Most important shot.
Hand grip view
Flip so label faces up. This shot drives OCR brand/model detection - get it sharp.
3. Anterior edge up
L: shot 3.R: shot 9
Front edge of device faces camera. Hook curves away.
Hand grip view
Hold by superior/inferior ends so front edge is exposed.
4. Posterior edge up
L: shot 4.R: shot 10
Back edge faces camera. Hook hidden behind body.
Hand grip view
Same grip as #3 but rotated 180 degrees. No hook silhouette.
5. Superior end up
L: shot 5.R: shot 11
Hook end points at camera. Top-down silhouette of body.
Hand grip view
Hold by inferior end; aim camera down the long axis from the hook side.
6. Inferior end up
L: shot 6.R: shot 12
Battery-door end points at camera. Bottom cross-section.
Hand grip view
Hold by superior end (or hook); shoot down the long axis. Battery door visible.
2. BTE table rig (legacy - hand-held flow is preferred)
6 orientations x 2 aids (L then R) = 12 shots per pair. Device on the table, camera always straight down.
Legacy protocol. Use the hand-held flow instead - it covers the same 6 anatomical orientations and beat this rig in real testing. Only fire this protocol if you specifically want a clean, calibrated overhead photo for register display. Do NOT shoot this AND the hand-held set on the same device - they're redundant.
Shoot order: Always L aid first (all 6 orientations 1-6), then R aid (all 6 orientations 7-12). Same anatomical axis sequence both times.
Anatomical naming: medial = inner (touches head, label-side); lateral = outer; anterior = front edge; posterior = back edge; superior = top end (hook); inferior = bottom end (shell base).
1. Lateral face up
L: shot 1.R: shot 7
Outer shell up. No label visible.
Camera view
2. Medial face up
L: shot 2.R: shot 8
Inner side up. Label visible.
Camera view
3. Anterior edge up
L: shot 3.R: shot 9
Device on its posterior edge. Front edge faces camera.
Device on its anterior edge. Back edge faces camera.
Camera view
Same thin silhouette, hook hidden behind (no protrusion).
5. Superior end up
L: shot 5.R: shot 11
Device standing on inferior end. Hook attachment faces camera.
Camera view
Oval cross-section (wider than tall) with hook stub.
6. Inferior end up
L: shot 6.R: shot 12
Device standing on superior end. Bottom of shell faces camera.
Camera view
Full cross-section showing the battery door.
Awkward orientations are fine. Some orientations are physically awkward - BTEs don't balance well on edges or ends - just hold them with a finger and shoot whatever silhouette you can.
3. Non-BTE shapes - RIC, ITE, CIC, IIC
Smaller in-ear devices. Different anatomy, different shot lists. Hand-held naturals for all; plain background where possible.
General rules: hand-held, indoor diffuse light, fill ~60% of frame. Use macro mode if your phone supports it for CIC/IIC.
RIC (Receiver-in-Canal)
9 shots per aid
Looks like a BTE but with a thin wire ending in a receiver-dome that sits in the ear canal.
Body (BTE-style): all 6 BTE orientations from the hand-held protocol above (lateral, medial, anterior, posterior, superior, inferior).
Receiver bud:
Shot 7 - receiver front (looking at the dome end)
Shot 8 - receiver side profile
Wire:
Shot 9 - full wire path from body to receiver, laid flat
Pinch the body to expose the wire-exit point in shot 9; keep wire from kinking.
ITE (In-the-Ear)
4 shots per aid
Custom-moulded faceplate, fills the concha. No external wire.
Shot 1 - faceplate up (controls, vent, mic ports visible)
Shot 2 - canal side (the side that goes into the ear, receiver port visible)
Shot 4 - posterior profile (rotated 180 degrees from #3)
Hold by the canal end so the faceplate is unobstructed in shot 1. The faceplate is where the brand/serial usually prints.
CIC (Completely-in-Canal)
3 shots per aid
Tiny, sits fully in the canal. Removal handle (clear filament) usually visible.
Shot 1 - faceplate end (looking at the outer end, removal handle visible)
Shot 2 - side profile (long axis horizontal)
Shot 3 - close-up of removal handle / pull-cord
Use macro mode if available.
IIC (Invisible-in-Canal)
2 shots per aid
Deepest-fitting style. Smaller than CIC. Often no visible controls.
Shot 1 - faceplate end (outer end, may show removal filament)
Shot 2 - canal end (inner end, receiver port)
Macro mode strongly recommended. Plain matte background (paper, cloth) so the device silhouette is clean.
4. Accessories
Non-aid items in the register: chargers, charging cases, domes, wax filters, tubing, remote controls. Plain background, hand-held or flat.
General rule per accessory: 2 shots - top view + side profile, on a plain background. Special cases below add shots.
End of session: one group shot of any matched set (e.g. charger + aid + charging cable together).
Chargers (standalone)
2 shots
Wall chargers, USB bricks, charging pads.
Shot 1 - top view (logos, model markings)
Shot 2 - side profile (port, cable exit)
Charging cases
4 shots
Combined charger + storage case for the aids.
Shot 1 - closed, top view
Shot 2 - closed, side profile
Shot 3 - open, empty (charging contacts visible)
Shot 4 - open, with aids seated
Keep case on a flat plain surface; camera straight down for shots 1 and 3/4.
Domes
2 shots + scale
Silicone tips for RIC/BTE receivers (open, closed, power, double).
Shot 1 - top view (opening visible if vented)
Shot 2 - side profile
Fill the frame - domes are tiny, so get close and use macro if you can.
Wax filters
2 shots
Tiny replaceable filters that sit at the receiver outlet.
Shot 1 - top view of the carrier/wheel (filters in slots)
Shot 2 - single filter close-up
Fill the frame - these are very small, so get as close as your camera focuses.
Macro mode strongly recommended.
Tubing
2 shots
Slim tubes or standard tubes that connect BTE hook to ear mould.
Shot 1 - laid flat, full length (note coil if pre-curved)
Shot 2 - close-up of connector end
Remote controls
2 shots
Hand-held remotes that pair with aids.
Shot 1 - top view (buttons, display, brand)
Shot 2 - back / battery compartment
Matched set group shot
1 shot
Final shot of the session for any matched accessory + aid set.
Arrange charger, cable, aids, and any included accessories on a plain background.
Top-down camera view; everything in one frame.
This shot documents what came as a kit - useful for the donor record and the audiologist's QA check.
Naming and storage: raw photos go to data/photos_nick_aids/<DEVICE_ID>/. Anatomical orientation is encoded in the manifest.json sidecar, not the filename - that way we can re-tag without renaming files.